When these buttons are pressed simultaneously, the lens iris is reset to the factory default setting. When these buttons are pressed simultaneously, the lens focus is set automatically if the specified camera is used. Selects a specific system unit in a multiple unit system.

To select a unit, press this button after entering the unit number with the numeric button. The selected unit address appears on the LED display. The unit that is assigned to number 1 can be selected by pressing this button. To select a unit, press this button after entered the unit number with the numeric button.

In combination with the numeric buttons, this button is also used to recall a preset position assigned to a specific camera. These buttons are used for numeric input, such as camera, monitor and unit numbers, and preset positions. CAM: Used for camera selection. To select a camera, enter the desired camera number with the numeric buttons, and then press this button. SET: Executes the currently highlighted setting in the setup menu. MON: Used for monitor selection and confirmation. To select a monitor, enter the desired monitor number with the numeric buttons, and then press this button.

The selected monitor number appears on the LED display. ESC: Used to escape from the currently highlighted selection and return to the previous menu of the setup menu. Pressing this button for 2 seconds or more will open the camera setup menu. Pressing it in combination with the numeric buttons after pressing the shift button will execute camera functions. Pressing this button for 2 seconds or more will open the setup menu of a system unit.

Enter a function number with the numeric keys, then press this button. Shifts the button function between the normal and the shift mode shown in half-tone print under the button on the template. The LED next to the button is lit in the shift mode. Activates the auto panning function of cameras provided with this feature. Pressing this button in the shift mode will change the camera picture from colour to black and white for better viewing in a dark place.

Activates the housing defroster of cameras provided with this feature. Pressing this button in the shift mode will turn on the AUX 2 function controlling accessories connected to the cameras or the system. Activates the housing wiper of cameras provided with this feature. Pressing this button in the shift mode will turn on the AUX 1 function controlling accessories connected to the cameras or the system.

Starts the camera patrol play. Resets system alarm when the alarm function is active. Pressing this button in the SHIFT mode will recall the alarm logs record of alarms activated in the past. Select a monitor, and then press this button to display the alarm logs on the monitor screen. Pressing this button after pressing the shift button again will cancel the function. Changes the display on the multiscreen monitor between the live picture of a camera and the playback picture of a recording device.

Zooms the camera picture or VCR playback picture displayed on the multiscreen monitor. Pressing this button in the shift mode will move the camera sequence one step forward from the step previously paused while a system unit provided with SEQ PAUSE e.

Pressing this button in the shift mode will select the picture of camera with the next higher number for display on the monitor while a system unit connected with cameras e. Pressing this button in the shift mode will move the camera sequence one step backward from the step previously paused while a system unit e.

Pressing this button in the shift mode will select the picture of the camera with the next lower number for display on the monitor while a system unit connected with cameras e.

Runs or stops a preset sequence in which a series of camera pictures is displayed in succession on the monitor screen for the specified duration. Pauses a sequence running on the selected monitor. In this mode, a series of camera pictures is displayed in pause on the monitor screen for the specified duration. The installation should be made by qualified service personnel or system installers according to the following instructions.

Camera No. Example 2 shows 4 Data Multiplex Units connected with 16 combination cameras, and 4 System Controllers. Note: When using cables other than those supplied, make sure to use shielded 4-wire twisted pair cable suitable for RS communication. An 8-bit DIP switch mounted on the rear panel specifies the communication mode, etc. Remove the DC plug from the rear of the controller. Set the switch referring to the table. Connect the DC plug to the controller.

The switch should be set to OFF when the controller is located in an intermediate position. The switch should be set to ON when setting up the controller. Remember to set this switch to the OFF position after completion of the setup operation. Bit 5 should be set to OFF when the controller is placed in an intermediate position, or set to ON when it is connected at the chain end.

Use a screw driver to rotate the switch so that the arrow comes to the number you wish. One controller within the multiple controller system must be assigned the number 1. Confirm that all necessary connections and switch settings are complete. Supply power to the controller. Turn on the power of cameras and other system units.

The controller is ready to enter the setup mode. The following buttons and joystick operations are used in the setup operation. There are three ways to select a parameter, but the following pages only describe the selection by use of the joystick. Instead of operating the joystick, you can enter the number enclosed in brackets with the numeric keys or press the plus and minus buttons. The [- - - - -] prompt appears. If password entry failed, the menu returns to [- - - - -].

Remember that this procedure also resets all other menu parameters to the default settings. In this menu, the communication speed bps: bits per second is selected.

The communication speed should match that of the other units connected in the communication chain. Select a parameter entering a bracket-enclosed number, e. Note: Selecting a slower rate e. Press the ESC button to go back to the previous menu. Select a parameter with the joystick. The default setting is None. In this menu a wait time is selected. The controller will retransmit data when there is no response during the specified wait time.

The default setting is Off. In this menu, a maximum of 9 system units is assigned to numeric buttons regardless of unit address. This is to avoid double-digit unit addresses which can occur in a large system with many units connected and could confuse operators. A frequently used system unit can be easily selected in normal operation by pressing one numeric button and then the UNIT A button.

The next 2 digits are the unit address assigned in the following procedures. The LED displays [A] while the next two digits are blinking. The LED displays [A], for example, when you enter unit address Repeat above the steps 2 to 5 as needed. Refer to the above description for Unit A button Assignment. The LED displays the registered password. Enter a 5-digit password with the numeric buttons. The default setting is []. In this menu, a 5-digit password for administrator certification is registered.

In this menu, password certification in normal operation is enabled or disabled. Select On or Off with the joystick controller. The default setting is On. This menu is for specifying the order in which combination cameras connected to the system are cleaned.

All combination cameras connected to the system are cleaned in the order specified here. Picture viewing is disabled during the cleaning process. The LED displays [no]. Use the numeric buttons to enter the number of the camera where cleaning is to start. Two animated digits appear in the left part of the LCD while the digits at right display the number of the camera being cleaned. When cleaning is finished, the number of the last camera cleaned is displayed without animation.

This menu is for specifying the order in which data communication between system units is tested prior to operating the system as a whole.

The LED displays [on] or [oF]. Enter the 2-digit unit number you wish to start with. The digits in the left part of the LCD display the unit number under test while 2 animated digits appear at right.

When testing is finished, the number of the last unit tested is displayed without animation. Enter a 2-digit number e. You can now confirm the test results of a specific unit. When Off is displayed, check connections, switch settings, etc. The operation starts with a log-in procedure. Pressing this button in the shift mode will turn on the AUX 2 function controlling accessories connected to the cameras or the system. Page 14 1 Controller No.

Remove the DC plug from the rear of the controller. Prior to Setup Do the following before entering the setup mode. The [- - - - -] prompt appears. The default setting is []. If password entry failed, the menu returns to [- - - - -]. Page 20 Unit A button Assignment In this menu, a maximum of 9 system units is assigned to numeric buttons regardless of unit address.

This is to avoid double-digit unit addresses which can occur in a large system with many units connected and could confuse operators. Page 21 Camera Cleaning This menu is for specifying the order in which combination cameras connected to the system are cleaned. All combination cameras connected to the system are cleaned in the order specified here. It proceeds to system unit selection, monitor selection and camera selection.

Alarm operations for the system such as alarm reset, suspension may be implemented. The operation ends with a log-out pro- cedure. When set to On, you will be prompted to enter your regis- tered password. Page Monitor Selection Monitor Selection A monitor is selected when multiple monitors are connected to a system unit e. Select the system unit connected to the monitor you wish to control. Some of the descriptions may not be applicable if they refer to devices not equipped in your sys- tem.

The operating procedures on the following pages assume that you have selected a system unit and a monitor. Page 27 Combination Camera Shortcuts The shortcuts listed below are available for controlling combination cameras. For more details, refer to the Operating Instructions included with the camera.

When a Receiver is installed in the system, an auxiliary device con- nected to it such as a buzzer or lamp will be also con- trolled. For more information, refer to the manual includ- ed with the Video Multiplexer. Page 30 Viewing Playback VCR playback pictures are displayed on the selected spot or multiscreen monitor. Playback pictures are displayed on the selected moni- tor.

For more information, refer to the manual included with the Digital Disk Recorder. Skip Playback REW. The alarm indicator changes from blinking to steady light when the alarm is automatically reset. You can use the controller to set up system units and cam- eras. This section describes the main remote setup procedures. Some of the descriptions may not be applicable if they refer to devices not equipped in your system.

Page Camera Patrol Learning 7. Page Camera Preset Position There are two ways of presetting camera positions. One is to use the camera setup menu of the combination camera and the other is to operate the System Controller as follows.

Select the desired system unit, monitor and camera. The lock can be released by sending a command from the computer. Page 40! During the setup, this button is used to select the desired parameter in the setup menu. The indicator lights up when the still mode is selected. A time lapse VCR will record pictures for later playback.

The spot monitor and multiscreen monitor will display live and playback pictures while these devices are being operated from System Controller WV-CUC. Alarm Sensor Page 47 4.